ZAPI Controllers Fault Codes

Alarms and fault codes for ZAPI AC inverters and pump controllers fitted to many electric forklifts. 108 codes.

ZAPI AC-0 SSL Sensored inverter (traction & pump configuration)

CodeFaultMeaning
MDI-PRC 1Wrong ConfigIt occurs the first time a controller is switched on when the non volatile eeprom memory is not initialized ye…
MDI-PRC 8Watch DogIt occurs when the embedded WATCH DOG protection is not able either to cut off the power stage when not trigge…
MDI-PRC 13EEPROM KOIt occurs due to a HW or SW defect of the non-volatile embedded memory supporting the controller regulations.…
MDI-PRC 16Aux Output KOThis alarm occurs when the feedforward PWM generated by the controller to supply the Electromechanical Brake a…
MDI-PRC 17Logic Failure #3It occurs when the circuit to limit via HW the current peak in the controller is active.…
MDI-PRC 18Logic Failure #2It occurs when the circuit, to compensate for the dead times of the sine waves, is failed.…
MDI-PRC 19Logic Failure #1This alarm signals that an overvoltage / undervoltage protection operation has occurred.…
MDI-PRC 30VMN LowBefore to switch the main contactor on, the SW turns on sequence the Top side Power Mosfets and expects the ph…
MDI-PRC 31VMN HighBefore to switch the main contactor on, the SW turns on sequence the Bottom side Power Mosfets and expects the…
MDI-PRC 37Contactor ClosedThe controller checks if the MC contact is closed when the coil isn’t driven, trying to discharge the capacito…
MDI-PRC 38Contactor OpenThe main contactor coil has been driven by the logic board, but the contactor does not close.…
MDI-PRC 53STBY I HighThis diagnosis is executed only when the main contactor is opened and asked to be closed (e.g. at key on or wh…
MDI-PRC 60Capacitor ChargeIn working condition, a resistance connected between the key and the Rail Capacitors, keeps the Rail Capacitor…
MDI-PRC 61High TemperatureThis alarm occurs when the temperature of the base plate is higher than 78 °C. Then the maximum current decrea…
MDI-PRC 65Motor TemperatureThis is just a warning with no effect on the truck performance. It occurs when the temperature of the motor wi…
MDI-PRC 67CAN Bus KOIt occurs if the controller does not receive any message from the CAN Bus line.…
MDI-PRC 70Encoder ErrorTwo consecutive readings of the encoder speed are too much different in between: because of the inertiality of…
MDI-PRC 73Thermic Sens KOWhen the output of the thermal sensor on the base plate is higher than 4.95 V or lower than 0.1 V, the sensor …
MDI-PRC 74Driver ShortedThis alarm occurs when the voltage on the Main Contactor is higher than expected: this means that the Main Con…
MDI-PRC 75Contactor DriverThis alarm occurs when the voltage on the Main Contactor is smaller than expected: this means that the Main Co…
MDI-PRC 76Coil ShortedThis alarm occurs when there is an overload on one of the following connections: CNA#1, CNA#3, CNA#4 and CNA#6…
MDI-PRC 78VACC Not OKThe test is made at key-on and after 20 sec that both the travel demands have turned disactive. This alarm occ…
MDI-PRC 79Incorrect StartThis is just a warning for an incorrect starting sequence.…
MDI-PRC 86Pedal Wire KOThe SW continuously checks for the connection of the two supply ends of the potentiometer in the accelerator. …
MDI-PRC 93Wrong Set BattWhen the key is turned ON, the controller check the battery voltage and verifies it is within a window around …
MDI-PRC 94Current Sens KOThis alarm occurs when the procedure for the maximum current set-up is in progress.…
MDI-PRC 99Check Up NeededThis is just a warning to call for the time programmed maintenance.…

ZAPI AC-0 SSL Sensored inverter (traction configuration)

CodeFaultMeaning
MDI-PRC 55Program Lift LeverThe SW continuously matches the potentiometer connected to CNA#18 with the Main Lifting/Lowering pair request …
MDI-PRC 70MDI Valve2 ShortThis alarm occurs on the MDI-PRC and the information is transferred via CAN Bus to the AC-0.…
MDI-PRC 71HandbrakeThis alarm occurs when the operator try to travel with the handbrake active.…
MDI-PRC 74MDI Drv 2 ShortThis alarm occurs on the MDI-PRC and the information is transferred via CAN Bus to the AC-0.…
MDI-PRC 75MDI Drv 2 OpenThis alarm occurs on the MDI-PRC and the information is transferred via CAN Bus to the AC-0.…
MDI-PRC 80Forw + BackThis alarm occurs when both the travel demands (Fwd and Bwd) are active at the same time.…
MDI-PRC 89MDI Pev Not OKThis alarm occurs on the MDI-PRC and the information is transferred via CAN Bus to the AC-0.…
MDI-PRC 90Lift + LowerThis alarm occurs when both a Lifting request and a Lowering request are active at the same time.…
MDI-PRC 90MDI Nevp1 Not OKThis alarm occurs on the MDI-PRC and the information is transferred via CAN Bus to the AC-0.…
MDI-PRC 91Lift Low ActiveThis is just a warning when a Lifting/Lowering request is active at key-on.…
MDI-PRC 92Input Error #1This alarm occurs when the PLD device has a failure. The PLD device is used for both, the Passive Emergency Ce…

ZAPI ACE0 / COMBIAC0 controller

CodeFaultMeaning
CAPACITOR CHARGECapacitor ChargeFollows the charging capacitor system: When the key is switched ON, the inverter tries to charge the power cap…
VMN LOWVMN Low1: start-up test. Before switching the LC on, the software checks the power bridge: it turns on alternatingly …
VMN HIGHVMN High1: Before switching the LC on, the software checks the power bridge: it turns on alternatingly the Low side Po…
POWER MOS SHORTEDPower Mos ShortedBefore switching the LC on, the software checks the power bridge: it turns on alternatingly the Low side and H…
COIL SHORTEDCoil ShortedThis alarm occurs when there is a short circuit of one of the coils connected to outputs of the Combiac0 (LC c…
DRIVER SHORTEDDriver ShortedThe driver of the main contactor coil is shorted or the coil is disconnected.…
CONTACTOR DRIVERContactor DriverThe LC coil driver is not able to drive the load. The device itself or its driving circuit is damaged.…
CONTACTOR OPENContactor OpenThe main contactor coil has been driven by the controller, but the contactor does not close.…
CONTACTOR CLOSEDContactor ClosedBefore driving the LC coil, the controller checks if the contactor is stuck. The controller drives the bridge …
AUX DRIVER SHORTEDAux Driver ShortedThe driver of the electromechanical brake coil is shorted.…
AUX DRIVER OPENAux Driver OpenThe driver of the electromechanical brake coil is not able to drive the load.…
POS EB SHORTEDPos EB ShortedThe output of the built in Smart Driver, which supplies the positive to the Electromechanical brake coil is hi…
LOGIC FAILURE #1Logic Failure #1This fault is displayed when the controller detects an overvoltage or undervoltage condition. Overvoltage thre…
LOGIC FAILURE #2Logic Failure #2Fault in the hardware section of the logic board which manages the phase’s voltage feedback.…
LOGIC FAILURE #3Logic Failure #3Hardware problem in the logic card circuit for high current (overload) protection.…
STBY I HIGHSTBY I HighThe current transducer or the current feedback circuit is damaged in the controller.…
WRONG SET BATTERYWrong Set BatteryAt start-up, the controller checks the battery voltage and verify it is within a window around the nominal val…
ANALOG INPUTAnalog InputThis alarm occurs when the A/D conversion of the analog inputs gives frozen value, on all of the converted sig…
ENCODER ERROREncoder ErrorThis fault is signalled in following conditions: the frequency supplied to the motor is higher than 40 Hz and …
TILLER ERRORTiller ErrorMismatch between the H&S input and the tiller input.…
WATCHDOGWatchdogThis is a safety related test. It is a self diagnosis test within the logic. The watch dog circuit is composed…
SMART DRIVER KOSmart Driver KOThe built in smart driver is open, not able to provide the electro mechanic brake positive.…
KEYOFF SHORTEDKeyoff ShortedThis fault is displayed when the controller detects a low logic level of Key-Off signal during Start-Up diagno…
EVP1 NOT OKEvp1 Not OKA) The EVP driver is shorted. B) The microcontroller detects a mismatch between the valve set-point and the di…
EVP2 NOT OKEvp2 Not OKA) The EVP2 driver is shorted. B) The microcontroller detects a mismatch between the valve set-point and the d…
PUMP VMN LOWPump VMN LowThe pump motor output is lower than expected, considering the pwm applied.…
PUMP VMN HIGHPump VMN HighThis test is carried out when the pump motor is turning (pwm applied). The pump motor output is higher than ex…
WRONG ZEROWrong ZeroThe outputs of the amplifiers (used to measure the traction motor voltage) are checked to be included into a r…
AUX BATT. SHORTAux Batt. ShortA) The coil on the aux output is not correctly connected. B) The smartdriver inside the controller is damaged.…
EMERGENCYEmergencyThe voltage on A3 is different than +Vbatt.…
FLASH CHECKSUMFlash ChecksumThe software was not correctly written into the flash memory or the flash memory is damaged.…
CURRENT SENS. KOCurrent Sens. KOOne of the current sensor, used to measure the value of the current on the motor phases, is damaged.…
SLIP PROFILESlip ProfileThere is an error on the choice of the parameters of the slip profile.…
FORW+BACKForw + BackThis alarm occurs when both the travel demands (Fwd and Bwd) are active at the same time.…
INCORRECT STARTIncorrect StartThis is a warning for an incorrect starting sequence.…
VACC NOT OKVACC Not OKThe test is made at key-on and after 20sec that both the travel demands have been turned off. This alarm occur…
HIGH TEMPERATUREHigh TemperatureThis alarm occurs when the temperature of the base plate is higher than 85°. Then the maximum current decrease…
BATTERY LOWBattery LowIt occurs when the battery charge is calculated being less than or equal to 10% of the full charge and the BAT…
EEPROM KOEEPROM KOIt’s due to a HW or SW defect of the non-volatile embedded memory supporting the controller parameters. This a…
MOTOR TEMPERATUREMotor TemperatureThis warning occurs when the temperature sensor is opened (if digital) or has overtaken the threshold of 150°C…
THERMIC SENSOR KOThermic Sensor KOThe output of the controller thermal sensor is out of range.…
CHECK UP NEEDEDCheck Up NeededThis is just a warning to call for the time programmed maintenance.…
DATA ACQUISITIONData AcquisitionAcquisition of the current gains.…
PEDAL WIRE KOPedal Wire KOThe SW continuously checks for the connection of the two supply ends of the potentiometer in the accelerator. …
TILLER OPENTiller OpenWarning: when the tiller is released, after a fixed period of time of standby (30 seconds) the main contactor …
CURRENT GAINCurrent GainThe Maximum current gain parameters are at the default values, which means the maximum current adjustment proc…
WAITING FOR NODEWaiting For NodeThe controller receives from the CAN the message that another controller in the net is in fault condition; as …
DEAD MAN ABSENTDead Man AbsentThis warning (presents only in trucks with “Dead Man” switch) appears when the “Dead Man” switch is open.…
CURRENT SENSOR LOWCurrent Sensor LowThe pump chopper current sensor feedback is too low (below 0.5V).…
VALVE COIL SHORTEDValve Coil ShortedThis alarm occurs when there is a short circuit on an on/off valve coil.…
EV1/5 DRIVER SHORTEDEV1/5 Driver ShortedElectrovalve EV1 or EV2 driver is shorted.…
EV2 DRIVER SHORTEDEV2 Driver ShortedElectrovalve EV2 driver is shorted.…
EV3 DRIVER SHORTEDEV3 Driver ShortedElectrovalve EV3 driver is shorted.…
EV4 DRIVER SHORTEDEV4 Driver ShortedElectrovalve EV4 driver is shorted.…
VALVE CONT DRIVERValve Cont DriverOne or more on/off valve drivers is not able to drive the load (cannot close).…
EVP DRIVER KOEVP Driver KOThe EVP valve driver is not able to drive the load (cannot close).…
EVP2 DRIVER KOEvp2 Driver KOThe EVP2 valve driver is not able to drive the load (cannot close).…
PUMP I NO ZEROPump I No ZeroIn standby condition (pump motor not driven), the feedback coming from the current sensor in the pump chopper …
PUMP I=0 EVERPump I=0 EverThis test is carried out when the pump motor is running, and it verifies that the current feedback sensor is n…
RAM WARNINGRam WarningChecksum of the ram failed.…
EEP WARNINGEep WarningEeprom checksum failed…
LIFT + LOWERLift + LowerThis alarm occurs when both forks movement requests(Lift + Lower) are active at the same time.…
CONT. DRV. EV1Cont. Drv. EV1The EV1 valve driver is not able to drive the load (cannot close).…
CONT. DRV. EV2Cont. Drv. EV2The EV2 valve driver is not able to drive the load (cannot close).…
CONT. DRV. EV3Cont. Drv. EV3The EV3 valve driver is not able to drive the load (cannot close).…
CONT. DRV. EV4Cont. Drv. EV4The EV4 valve driver is not able to drive the load (cannot close).…
CONT. DRV. EV5Cont. Drv. EV5The EV5 valve driver is not able to drive the load (cannot close).…
TH. PROTECTIONTh. ProtectionThe controller detected a high temperature, and the performance of the motor is limited.…
PUMP VACC NOT OKPump VACC Not OKThe minimum of the lift potentiometer is not correctly set.…
SENS. MOT. TEMP.Sens. Mot. Temp.A) The motor temperature sensor is not correctly connected to A22. B) The motor temperature sensor is damaged.…

Every entry names its source on its own page. Always confirm in the service manual for your exact model.