What this code means
This alarm occurs when the temperature of the base plate is higher than 78 °C. Then the maximum current decreases proportionally with the temperature increases from 78 °C up to 100 °C. At 100 °C the current is limited to 0 Amps.
Applies to: ZAPI AC-0 SSL Sensored inverter (traction & pump configuration).
Possible causes / checks (from the source)
Improve the air cooling of the controller.
Need the part?
If diagnosis points to a failed sensor, solenoid, controller or harness part, send us the code (MDI-PRC 61), machine model and serial number — we quote genuine and OEM replacement parts for export.
Ask for the replacement part on WhatsAppSource: ZAPI AC-0 SSL Sensored User Manual (AE0ZP0EC) via ManualsLib; corroborated by ZAPI AC0 Inverter manual (eastelite.co.za). Cross-checked in two independent sources. Compiled 2026-10-30. No manufacturer affiliation.