Home › ZAPI Controllers › MDI-PRC 31
What this code means
Before to switch the main contactor on, the SW turns on sequence the Bottom side Power Mosfets and expects the phase V voltage falls to GND value. If the phase V remains high level this alarm occurs.
Applies to: ZAPI AC-0 SSL Sensored inverter (traction & pump configuration).
Possible causes / checks (from the source)
Two possibilities: - At least a motor phase is not connected to the controller or broken. - A Power Failure (e.g. a Bottom side Power Mosfet opened) or a Logic Failure occurred in the controller. In this case it is necessary to replace the controller.
Need the part?
If diagnosis points to a failed sensor, solenoid, controller or harness part, send us the code (MDI-PRC 31), machine model and serial number — we quote genuine and OEM replacement parts for export.
Ask for the replacement part on WhatsAppSource: ZAPI AC-0 SSL Sensored User Manual (AE0ZP0EC) via ManualsLib. Cross-checked in two independent sources. Compiled 2026-10-30. No manufacturer affiliation.