Home › ZAPI Controllers › CURRENT SENS. KO
What this code means
One of the current sensor, used to measure the value of the current on the motor phases, is damaged.
Applies to: ZAPI ACE0 / COMBIAC0 controller.
Possible causes / checks (from the source)
This type of fault is not related to external components, replace the controller. 12.4 Warnings overview Machine status Restart Error code Description Effect when the test is procedure done Slip profile - Error on the parameters of the slip Traction is stopped start-up, stand-by, Traction MDI CAN 99 profile setting. traction request Forward+back The travel demands are active in both Traction is stopped start-up, stand-by, Traction ward - MDI directions at the same time traction request CAN 80 Incorrect start - Incorrect starting sequence Traction is stopped start-up, stand-by, Traction MDI CAN 79 traction request Vacc not ok - The acceleretor value is higher than Traction is stopped start-up
Need the part?
If diagnosis points to a failed sensor, solenoid, controller or harness part, send us the code (CURRENT SENS. KO), machine model and serial number — we quote genuine and OEM replacement parts for export.
Ask for the replacement part on WhatsAppSource: ZAPI COMBIAC0 & ACE0 User Manual (AF6ZP0AG) via Heli Canada document library (doc.heliforklift.ca). Single published source — confirm against the manual for your exact model before ordering parts. Compiled 2026-10-30. No manufacturer affiliation.