ZAPI Controllers · MDI-PRC 78
VACC Not OK

What this code means

The test is made at key-on and after 20 sec that both the travel demands have turned disactive. This alarm occurs if the ACCELERATOR reading in the TESTER menu is higher than 1.0 V (it means the wiper of the potentiometer is higher than 2 Vdc) when the accelerator is released.

Applies to: ZAPI AC-0 SSL Sensored inverter (traction & pump configuration).

Possible causes / checks (from the source)

Check the mechanical calibration and the functionality of the potentiometer.