Home › ZAPI Controllers › MDI-PRC 75
What this code means
This alarm occurs when the voltage on the Main Contactor is smaller than expected: this means that the Main Contactor Coil has a null voltage when supplied.
Applies to: ZAPI AC-0 SSL Sensored inverter (traction & pump configuration).
Possible causes / checks (from the source)
Check the coils of the Main Contactor (CNA#1) is not short circuited. If it isn’t, probably it is necessary to replace the controller because the driver of the Main Contactor is broken.
Need the part?
If diagnosis points to a failed sensor, solenoid, controller or harness part, send us the code (MDI-PRC 75), machine model and serial number — we quote genuine and OEM replacement parts for export.
Ask for the replacement part on WhatsAppSource: ZAPI AC-0 SSL Sensored User Manual (AE0ZP0EC) via ManualsLib. Single published source — confirm against the manual for your exact model before ordering parts. Compiled 2026-10-30. No manufacturer affiliation.