Home › ZAPI Controllers › MDI-PRC 79
What this code means
This is just a warning for an incorrect starting sequence.
Applies to: ZAPI AC-0 SSL Sensored inverter (traction & pump configuration).
Possible causes / checks (from the source)
The possible reasons for this alarm are (use the readings in the TESTER to facilitate the troubleshooting): a) A travel demand active at key on b) The tiller switch active at key-on c) The H&S input active at key-on d) The Quick inversion active at key-on A failure in the logic is possible too. When all of the above conditions were checked and nothing was found, replace the controller.
Need the part?
If diagnosis points to a failed sensor, solenoid, controller or harness part, send us the code (MDI-PRC 79), machine model and serial number — we quote genuine and OEM replacement parts for export.
Ask for the replacement part on WhatsAppSource: ZAPI AC-0 SSL Sensored User Manual (AE0ZP0EC) via ManualsLib; corroborated by ZAPI AC0 Inverter manual (eastelite.co.za). Cross-checked in two independent sources. Compiled 2026-10-30. No manufacturer affiliation.