Home › ZAPI Controllers › HIGH TEMPERATURE

ZAPI Controllers · HIGH TEMPERATURE
High Temperature

What this code means

This alarm occurs when the temperature of the base plate is higher than 85°. Then the maximum current decreases proportionally with the temperature increases from 85° up to 105°. At 105° the Current is limited to 0 Amps.

Applies to: ZAPI ACE0 / COMBIAC0 controller.

Possible causes / checks (from the source)

Improve the air cooling of the controller. If the alarm is signalled when the controller is cold, the possible reasons are a thermal sensor failure or a failure in the logic card. In this case, it is necessary to replace the controller.

Need the part?

If diagnosis points to a failed sensor, solenoid, controller or harness part, send us the code (HIGH TEMPERATURE), machine model and serial number — we quote genuine and OEM replacement parts for export.

Source: ZAPI COMBIAC0 & ACE0 User Manual (AF6ZP0AG) via Heli Canada document library (doc.heliforklift.ca). Single published source — confirm against the manual for your exact model before ordering parts. Compiled 2026-10-30. No manufacturer affiliation.