Home › ZAPI Controllers › MDI-PRC 92

ZAPI Controllers · MDI-PRC 92
Input Error #1

What this code means

This alarm occurs when the PLD device has a failure. The PLD device is used for both, the Passive Emergency Cell (see 4.3.3) and a Multiplexer on the Main Lifting/Lowering requests. This Multiplexer exits the Lifting and the Not Lifting level on two distinct addresses. When the Lifting and the Not Lifting outputs have the same Logic Level the PLD device has failed and this alarm occurs.

Applies to: ZAPI AC-0 SSL Sensored inverter (traction configuration).

Possible causes / checks (from the source)

It is necessary to replace the controller.

Need the part?

If diagnosis points to a failed sensor, solenoid, controller or harness part, send us the code (MDI-PRC 92), machine model and serial number — we quote genuine and OEM replacement parts for export.

Source: ZAPI AC-0 SSL Sensored User Manual (AE0ZP0EC) via ManualsLib. Single published source — confirm against the manual for your exact model before ordering parts. Compiled 2026-10-30. No manufacturer affiliation.