Home › ZAPI Controllers › MDI-PRC 90
What this code means
This alarm occurs when both a Lifting request and a Lowering request are active at the same time.
Applies to: ZAPI AC-0 SSL Sensored inverter (traction configuration).
Possible causes / checks (from the source)
If the MDI-PRC is absent, check only the wiring of the main Lifting/Lowering pair (CNB#8 and CNB#9); if the MDI-PRC is present check also the wiring of the Aux Lifting/Lowering pair (CNA#14 and CNA#15). (Use the readings in the TESTER to facilitate the troubleshooting). A failure in the logic is possible too. When you have verified the Lifting/Lowering switches are fine working and the wiring is right, it is necessary to replace the controller.
Need the part?
If diagnosis points to a failed sensor, solenoid, controller or harness part, send us the code (MDI-PRC 90), machine model and serial number — we quote genuine and OEM replacement parts for export.
Ask for the replacement part on WhatsAppSource: ZAPI AC-0 SSL Sensored User Manual (AE0ZP0EC) via ManualsLib. Single published source — confirm against the manual for your exact model before ordering parts. Compiled 2026-10-30. No manufacturer affiliation.