Home › Hangcha Forklifts › 2,3
What this code means
START LOCKOUT - the starting sequence is wrong.
Applies to: CPD10/15/20/25/30/35J C1, CPD10/15/18/20/25/30/35J C2, CPD40/45/50J C2 electric - traction (tow) controller, LED code / programmer LCD.
Possible causes / checks (from the source)
Improper sequence of direction and throttle inputs; wrong START LOCKOUT type selected; misadjusted throttle potentiometer; sequencing delay too short.
Need the part?
If diagnosis points to a failed sensor, solenoid, controller or harness part, send us the code (2,3), machine model and serial number — we quote genuine and OEM replacement parts for export.
Ask for the replacement part on WhatsAppSource: Hangcha CPD J-series service manual fault table of traction (tow) controller, as reproduced by ForkliftPDFManuals.com and Truck-FreeWorkshop.com (two libraries agree). Cross-checked in two independent sources. Compiled 2026-10-30. No manufacturer affiliation.