What this code means
Built-in charger error: the safety timer was activated during charging.
Applies to: 7FBE10-20 built-in charger (OPT).
Possible causes / checks (from the source)
AC power supply defect or power failure; power cable defect; display defect; blown DC-side fuse. Manual checks: AC input voltage 200-220 V at supply and at power plug; charger timer test; DC fuse continuity.
Need the part?
If diagnosis points to a failed sensor, solenoid, controller or harness part, send us the code (F6-1), machine model and serial number — we quote genuine and OEM replacement parts for export.
Ask for the replacement part on WhatsAppSource: Toyota 7FBE10-20 Service Manual (2003), Charger Troubleshooting. Single published source — confirm against the manual for your exact model before ordering parts. Compiled 2026-10-30. No manufacturer affiliation.