What this code means
Charge air temperature high torque derate: the temperature signal from the boost pressure & temperature sensor exceeds the upper limit of temperature control; the controller restricts engine output (engine output lowers). Action level L03.
Applies to: PC200-8/PC200-8M0 excavator (engine controller).
Possible causes / checks (from the source)
Manual troubleshooting: (1) lowered cooling performance of the aftercooler — check fan belt looseness/damage, insufficient cooling air, clogging of aftercooler fins; (2) abnormal rise of turbocharger outlet temperature; (3) defective boost temperature sensor (see CA153/CA154).
Need the part?
If diagnosis points to a failed sensor, solenoid, controller or harness part, send us the code (CA488), machine model and serial number — we quote genuine and OEM replacement parts for export.
Ask for the replacement part on WhatsAppSource: Komatsu PC200-8M0 Shop Manual (SEN06134-00) – Troubleshooting by failure code [CA488]. Cross-checked in two independent sources. Compiled 2026-10-30. No manufacturer affiliation.