Sensor Supply 1 Voltage High Error

What this code means

Sensor power supply No. 1 voltage is too high (high error). Action level L03.

Applies to: PC200-8/PC200-8M0 excavator (engine controller).

Need the part?

If diagnosis points to a failed sensor, solenoid, controller or harness part, send us the code (CA386), machine model and serial number — we quote genuine and OEM replacement parts for export.

Source: Komatsu PC200-8M0 Shop Manual (SEN06131-00) – Failure codes table. Cross-checked in two independent sources. Compiled 2026-10-30. No manufacturer affiliation.