Heli Forklifts Fault Codes

Fault codes for Heli electric and engine forklifts, from Heli's own published manuals. 33 codes.

G Series 3-wheel electric CPD13SH/15SH, Danaher control system (OPT10 meter codes, service manual Table 8-2)

CodeFaultMeaning
101Accelerator switch active at key-onACCEL SWITCH ACTIVE AT KEY ON - the acceleration switch is on when the key is switched on.…
102Direction switch active at key-onDIR. SWITCH ACTIVE AT KEY ON - at least one of the direction switches is on when the key is switched on.…
103Both direction switches onDIR. SWITCH BOTH ON ERROR - both of the direction switches are on at the same time.…
104Traction potentiometer value out of rangeTRACT POT VALUE OUT OF RANGE - the value of the traction potentiometer is out of range (below 30 or above 2800…
105Traction switch off with large pot valueTRACT SWITCH OFF WITH LARGE POT VALUE - the acceleration switch is off but the value of the traction potentiom…
111CAN communication errorCAN COMMUNICATION ERROR - CAN communication error in the Danaher control system.…
114Battery low errorBATTERY LOW ERROR - the battery is low; BDI value below 25 gives a warning, below 15% slows the truck.…
121Pump potentiometer value out of rangePUMP POT VALUE OUT OF RANGE ERROR - the value of the pump potentiometer is out of range (below 30 or above 280…
125Main contactor off errorMAIN CONTACTOR OFF ERROR - the main contactor is off.…
302ACS temperature highACS TEMP HIGH - the ACS (controller) temperature is higher than 85 C.…
305Motor temperature highMOTOR TEMP HIGH - the motor temperature is higher than 145 C.…
308High voltageHIGH VOLTAGE - the ACS voltage is higher than 98 V.…
309Low voltageLOW VOLTAGE - the ACS voltage is lower than 60 V.…
351Short circuitSHORT CIRCUIT - there is a short circuit among B+, B-, U, V, W.…
355Capacitor not chargingCAP. NOT CHARGING - the ACS capacitor is not charged up to 85% within 10 seconds.…
360Low voltage (severe)LOW VOLTAGE - the ACS voltage is lower than 40 V.…

G3 Series IC CPCD20-35 with fingertip control (J1939 SPN/FMI codes)

CodeFaultMeaning
SPN 520705 FMI 11Power supply voltage too lowPower supply voltage is too low; controller output is cut off (SPN 520705, hex 0x7F201).…
SPN 520706 FMI 11Emergency stop switch engagedEmergency stop switch engaged (SPN 520706, hex 0x7F202).…
SPN 520707 FMI 2Controller temperature too highController temperature too high (above 115 C) (SPN 520707, hex 0x7F203).…
SPN 520708 FMI 4Power supply too low (3 s)Power supply is too low, continuous for 3 seconds (SPN 520708, hex 0x7F204).…
SPN 520709 FMI 3Power supply voltage too highPower supply voltage is too high (SPN 520709, hex 0x7F205).…
SPN 520710 FMI 4VSS1 voltage too lowVSS1 voltage too low (SPN 520710, hex 0x7F206).…
SPN 521472 FMI 0Seat switch short to powerSeat switch shorted to power (SPN 521472, hex 0x7F500).…
SPN 521472 FMI 13Seat switch input range errorSeat switch input range error (also listed: seat switch input calibration error) (SPN 521472, hex 0x7F500).…
SPN 521473 FMI 1Work release switch shorted to groundWork release switch shorted to ground (SPN 521473, hex 0x7F501).…
SPN 521474 FMI 19CAN2 bus offCAN2 bus off (SPN 521474, hex 0x7F502).…
SPN 521476 FMI 11CAN2 signal interruptionCAN2 signal interruption (SPN 521476, hex 0x7F504).…
SPN 521477 FMI 11Fingertip switch counter verification errorFingertip switch counter verification error (SPN 521477, hex 0x7F505).…
SPN 521478 FMI 11Fingertip switch CRC check errorFingertip switch CRC check error (SPN 521478, hex 0x7F506).…
SPN 520502 FMI 4Left side shift valve short to groundLeft side shift valve shorted to ground (SPN 520502, hex 0x7F136).…
SPN 520502 FMI 3Left side shift valve open or short to powerLeft side shift valve open circuit or shorted to power (SPN 520502, hex 0x7F136).…
SPN 520517 FMI 13Lift valve fault detectedLift valve fault detected by the controller (SPN 520517, hex 0x7F145).…
SPN 520518 FMI 4Lowering valve short to groundLowering valve shorted to ground (SPN 520518, hex 0x7F146).…

Every entry names its source on its own page. Always confirm in the service manual for your exact model.