Home › Curtis fault codes › Code 69
Possible causes (from the Curtis manual)
1. External load on the 5V and 12V supplies draws either too much or too little current. 2. Fault Checking Menu parameters Ext Supply Max and Ext Supply Min are mis-tuned. 3. See Monitor menu » Outputs: Ext Supply Current.
When it sets / how it clears
Set: The external supply current (combined current used by the 5V supply [pin 26] and 12V supply [pin 25]) is either greater than the upper current threshold or lower than the lower current threshold. The two thresholds are defined by the External Supply Max and External Supply Min parameter settings (page 52). Clear: Bring the external supply current within range.
Effect of the fault
None, unless a fault action is programmed in VCL.