Home › Curtis fault codes › Code 35
Curtis Code 35
PD Open/Short — controllers 1234 / 1236 / 1238
Possible causes (from the Curtis manual)
1. Open or short on driver load. 2. Dirty connector pins. 3. Bad crimps or faulty wiring.
When it sets / how it clears
Set: Proportional driver (pin 2) is either open or shorted. Clear: Correct open or short, and cycle driver.
Effect of the fault
ShutdownPD.
Curtis 1234/1236/1238 controllers are fitted to many electric forklifts and industrial trucks (including models from Chinese brands that use Curtis control). If your display shows code 35 with a Curtis controller, this entry applies; the vehicle maker’s manual may add model-specific notes.
Need the part?
For controller, contactor, sensor or throttle parts, send us the code (Curtis 35), controller model and vehicle model on WhatsApp — we quote genuine and OEM parts for export.
Ask for the replacement part on WhatsAppSource: Curtis 1234/36/38 Controller Manual, OS 11, Section 8 Diagnostics & Troubleshooting, Table 5. Compiled 2026-10-29. No affiliation with Curtis Instruments.