Home › Curtis fault codes › Code 25
Curtis Code 25
+5V Supply Failure — controllers 1234 / 1236 / 1238
Possible causes (from the Curtis manual)
1. External load impedance on the +5V supply (pin 26) is too low. 2. See Monitor menu » outputs: 5 Volts and Ext Supply Current.
When it sets / how it clears
Set: +5V supply (pin 26) outside the +5V±10% range. Clear: Bring voltage within range.
Effect of the fault
None, unless a fault action is programmed in VCL.
Curtis 1234/1236/1238 controllers are fitted to many electric forklifts and industrial trucks (including models from Chinese brands that use Curtis control). If your display shows code 25 with a Curtis controller, this entry applies; the vehicle maker’s manual may add model-specific notes.
Need the part?
For controller, contactor, sensor or throttle parts, send us the code (Curtis 25), controller model and vehicle model on WhatsApp — we quote genuine and OEM parts for export.
Ask for the replacement part on WhatsAppSource: Curtis 1234/36/38 Controller Manual, OS 11, Section 8 Diagnostics & Troubleshooting, Table 5. Compiled 2026-10-29. No affiliation with Curtis Instruments.